Product Details:
Minimum Order Quantity | 12 Piece |
Deliver | India and Foreign Countries |
Heat Exchanger Material | Ceramic Coated Aluminum Tubes |
Surface Area | 0.067 m square / 677cm square |
Cardioplegia Solution Inlet | 1/4"(6.4mm) |
Blood Flow Range | 3000 ml/min |
Priming Volume (Device Only) | 34 ml |
Product Code | ACD677-1441 |
Cardioplegia delivery system with an improved heat exchanger module/unit TM delivers the desired performance in its segment. This System is designed and developed considering all the essential aspects related to cardioplegia systems i.e. rapid priming efficiency, higher coefficient of heat exchange, lower priming volume and pressure drop (flow resistance), and sufficient capacity to trap gross air.
Additional Information:
Product Details:
Minimum Order Quantity | 6 Piece |
Material | Polystyrene |
Usage/Application | Hospital |
Deliver | India and Foreign Countries |
Storage Capacity | 3000 ml |
Maximum Flow Rate | 8 L/min |
Maximum Rated Negative Pressure | 300mmHg |
Blood Outlet Port | 3/8" |
Blood Inlet Ports | 3 nos., 1/4" |
Additional Information:
Product Details:
Usage/Application | Hospital |
Priming Volume (Device Only) | 34 ml |
Product Code | ACD677-41A |
Blood Flow Range | 3000 ml/min |
Deliver | India and Foreign Countries |
Cardioplegia Solution inlet | 1/4"(6.4mm) |
Material | Polycarbonate |
Surface Area | 0.067 m square / 677cm square |
Heat Exchanger Material | Ceramic Coated Aluminum Tubes |
MOST BENEFITED SPECIFICATION
LARGEST EFFECTIVE SURFACE AREA OF HEAT EXCHANGER : 0.0435 Sq. M. AND MINIMUM PRIMING VOLUME 24 ml
ARTERIOUS BCD BLOOD FLOW DIRECTION :
Blood and Water Both opposite direction flow AND Maximum Effective surface area with Lowest Priming Volume All 3 important point for Heat exchanger, Also All are available in single device ARTERIOUS BCD it’s not available in world any company BCD
Blood enter in Bottom side Goes To Upper side and then goes to down side
ARTERIOUS BCD BLOOD FLOW And Water FLOW DIRECTION: Enter Bottom 50% surface area BLOOD and WATER both Upper Direction, Next 50% surface area Blood goes down direction and water go upper direction BOTH opposite direction Very important for heat exchange
ARTERIOUS BCD BLOOD FLOW DIRECTION: ADULT: Effective surface area 0.0667 sq.m. and Priming Volume 34ml
Paediatric BCD : Effective surface area 0.0435 sq.m. and Priming Volume 24ml
Additional Information:
Product Details:
Minimum Order Quantity | 8 Piece |
Usage/Application | Open Heart Surgery |
Material | PVC |
Type | Surgical Equipments |
Brand | Spictra |
Units Per Pack | 6 |
Priming volume | 40 ml |
Deliver | India and Foreign Countries |
Country of Origin | Made in India |
Additional Information:
Product Details:
Minimum Order Quantity | 6 Piece |
Type | Cardiovascular perfusion device |
Usage/Application | Hospital |
Deliver | India and Foreign Countries |
Units Per Pack | 6 |
Reservoir Capacity | 2000 ml |
Packaging Type | Box |
Country of Origin | Made in India |
CARDIOPLEGIA DELIVERY SYSTEM use in cardiovascular thoracic open heart surgery.
Cardioplegia is the international and temporary cessation of cardiac activity, primarily used in cardiac surgery. As known as myocardial protection system, the product is designed for safer and more effective delivery.
Additional Information: